Hebei Yusen Metal Wire Mesh CO.,Ltd.

Steel Fiber For A Better Life.

Manufacturer from China
Active Member
4 Years
Home / Products / Glued Steel Fiber /

Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue

Contact Now
Hebei Yusen Metal Wire Mesh CO.,Ltd.
City:hengshui
Country/Region:china
Contact Person:MsAlice Wang
Contact Now

Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue

Ask Latest Price
Video Channel
Brand Name :Yusen
Model Number :YS-65/35BG
Certification :ISO , CE
Place of Origin :China
MOQ :1T
Payment Terms :L/C, T/T, , Western Union, MoneyGram
Supply Ability :2000T/m
Delivery Time :10days
Packaging Details :1.1*1.1*1.1m pallet
Product name :Concrete Glued Hooked End Metal Steel Fiber
Material :Steel Wire
Secondart :Not
Shape :Hooked and deformed
Application :Bulk heavy warehouse
Tensile strength :1165Mpa
Standard :ISO8001
Dosage :15kgs
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Concrete Glued Hooked End Metal Steel Fiber

Glued Steel Fiber Introduction

Steel fiber concrete flooring can provide superior resistance to minimize cracks in hardened concrete, as well as maximum resistance to withstand heavy loads, either dynamic or static. If you decide to use steel fiber concrete flooring, you can select to use a ‘joint-less floor’. Joint-less floors are floors that have minimal joints, providing spaces without joints as large as 40 or 50-meter span wide.

Steel fiber dosage will vary greatly upon the project intended use, and the types of mesh being replaced. Common dosages are in the range between 20-30kg/m3 to 40-50kg/m3 for joint-less floors

Typically the fibers are added at the batch plant, just after all concrete aggregates are being mixed. Some people would request to have the fiber added at the job site, but then the QA/QC should have more control on how much fiber is added. The steel fiber manufacturer can provide guidance on how to mix and the amount needed to obtain the desired results. Be aware that if you add too much fiber, it might show up at the surface when finishing the concrete so be cautious about the amounts being mixed.

Glued Steel Fiber Specs

Glued
Steel Fiber
Model Diameter (mm) Length (mm) Aspect ratio (mm) Tensile strength (MPa)
YS-60/60BG 1 60 60 ≥1100
YS-50/50BG 1 50 50 ≥1100
YS-65/60BG 0.9 60 65 ≥1100
YS-55/50BG 0.9 50 55 ≥1100
YS-80/60BG 0.75 60 80 ≥1100
YS-45/35BG 0.75 35 45 ≥1100
YS-55/30BG 0.55 30 55 ≥1100
YS-60/30BG 0.5 30 60 ≥1100
YS-50/25BG 0.5 25 50 ≥1100
YS-60/25BG 0.4 25 60 ≥1100

Advance of End Hooked Glued Steel Fiber

  • Improved flexural properties
  • Reduced absorption of water, chemicals, etc.
  • Can be used on fast track schedule
  • Easier positioning of joints
  • Reduced site labor for managing steel reinforcement
  • Reduced project costs
  • Increased impact and abrasion resistance
  • Even distribution of fibers throughout the concrete

Technical and engineering support

  • We support you at everytime
  • Setting up your project specification
  • Recommend the most appropriate fiber type to dosage rates to guarantee performance and comply with the specifications.

Package and Delivery:

Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue

Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue

Inquiry Cart 0